Loading SEN workspace
Preparing the latest information…
Preparing the latest information…
Select an image, then move the pointer over the large image to inspect details. Tap the large image to toggle zoom on touch devices.
Honeywell
Honeywell CSLA2CF Open-Loop Hall Effect Current Sensor for bidirectional AC/DC current measurement up to ±125A peak. Features a 6–12V DC supply, ratiometric analog voltage output, 19.6mV/A-per-turn sensitivity at 8V and fast 3µs response time. PCB bottom-mount design for industrial power, motor-control, power-supply and current-monitoring applications. Mouser #: 785-CSLA2CF.
Final pricing may vary by configuration, quantity, delivery and project requirements.
The Honeywell CSLA2CF is a board-mount, open-loop Hall-effect current sensor designed for non-contact measurement of both AC and DC current. Mouser identifies this exact component under stock number 785-CSLA2CF. :contentReference[oaicite:0]{index=0}
The sensor measures current passing through its aperture and provides a ratiometric analog voltage output. The CSLA2CF is specified for a peak sensed-current range of ±125A, operates from a 6V to 12V DC supply, and has a typical response time of approximately 3µs. :contentReference[oaicite:1]{index=1}
| Manufacturer | Honeywell |
| Manufacturer Part Number | CSLA2CF |
| Mouser Number | 785-CSLA2CF |
| Series | CSLA |
| Product Type | Board-Mount Current Sensor |
| Sensing Technology | Hall Effect |
| Sensor Configuration | Open Loop |
| Current Measurement | AC / DC |
| Sensed Current Range | ±125A Peak |
| Number of Channels | 1 |
| Supply Voltage | 6V to 12V DC |
| Maximum Supply Current | 20mA |
| Output Type | Ratiometric Analog Voltage |
| Nominal Offset Voltage | VCC / 2 |
| Sensitivity at 8V Supply | 19.6mV/A per Turn |
| Sensitivity Tolerance | ±1.3% |
| Response Time | 3µs |
| Operating Temperature | -25°C to +85°C |
| Mounting | PCB Bottom Mount / Through-Hole |
The CSLA2CF can measure bidirectional current and is suitable for both AC and DC applications. Honeywell specifies a sensed-current range of ±125A peak for this exact model. :contentReference[oaicite:2]{index=2}
The conductor carrying the measured current passes through the sensor aperture. The Hall-effect sensing system detects the magnetic field generated by that current and produces a corresponding analog voltage output, providing electrical isolation between the measured current path and the sensor electronics.
With a specified 3µs response time, the CSLA2CF is suitable for applications requiring rapid monitoring of changing current levels. :contentReference[oaicite:3]{index=3}